Fire Hydrants, Dry Risers and Wet Risers

Servicing and testing fire hydrants, as well as dry and wet risers, are critical procedures for ensuring the effectiveness of firefighting systems in buildings and communities. Both Irish and European standards provide guidelines for the maintenance and testing of these essential fire safety equipment.

Fire Hydrants

Fire hydrants are outdoor fixtures connected to the water supply system, providing firefighters with access to water for extinguishing fires. In Ireland and across Europe, the maintenance and testing of fire hydrants are regulated by standards such as IS 384:2018 and EN 14384. These standards outline the requirements for the installation, inspection, and maintenance of fire hydrants.

Routine inspections of fire hydrants involve checking for any visible damage, corrosion, or blockages. Annual flow tests are conducted to ensure that the hydrants deliver an adequate flow of water at the required pressure. Pressure tests may also be performed periodically to verify the integrity of the hydrant’s components and connections.

g6366f64c43ce045b8d70a78985bcb8a71417a2e9be2cbc1d700d533c60efcefe7679593531a26c6f26e6433788d22c41_1280-270064.jpg

Dry and Wet Risers

Dry and wet risers are vertical pipes installed in buildings, allowing firefighters to access water at various levels for firefighting purposes. Dry risers are empty pipes that are filled with water by firefighters when needed, while wet risers are constantly charged with water.

In Ireland, the maintenance and testing of dry and wet risers are governed by standards such as IS 335:2009 and IS 341:2015. 

g6366f64c43ce045b8d70a78985bcb8a71417a2e9be2cbc1d700d533c60efcefe7679593531a26c6f26e6433788d22c41_1280-270064.jpg

These standards specify the design, installation, testing, and maintenance requirements for riser systems.

Routine inspections of dry and wet risers involve checking for leaks, blockages, and structural integrity. Flow tests are conducted annually to ensure that water can be delivered effectively to all outlets. Pressure tests may also be carried out periodically to verify the integrity of the riser system.

pexels-photo-19107333-19107333.jpg

Compliance and Safety

Adherence to Irish and European standards for the servicing and testing of fire hydrants, dry, and wet risers is essential for ensuring the reliability and effectiveness of firefighting systems. Regular maintenance and testing help identify and rectify any issues promptly, ensuring that these critical fire safety equipment are ready for use in emergencies. By complying with these standards, building owners and managers can contribute to the safety of occupants and properties, providing peace of mind in the event of a fire.

pexels-photo-19107333-19107333.jpg

Enhance Your Safety with Reliable Fire Hydrants, Dry Risers, and Wet Risers!

Ensure effective firefighting systems in buildings and communities through servicing and testing of fire hydrants, dry, and wet risers, in accordance with Irish and European standards.